Fabrication of Flexible and Biocompatible Electrochemical Sensor for Liver Enzyme Activity Monitoring
- 주제어 (키워드) flexible and biocompatible electrochemical sensor , hydrogel coating , liver enzyme , laser-induced graphene
- 발행기관 서강대학교 일반대학원
- 지도교수 신관우
- 발행년도 2025
- 학위수여년월 2025. 2
- 학위명 석사
- 학과 및 전공 일반대학원 화학과
- 실제 URI http://www.dcollection.net/handler/sogang/000000079766
- UCI I804:11029-000000079766
- 본문언어 영어
- 저작권 서강대학교 논문은 저작권 보호를 받습니다.
목차
1. Introduction 5
2. Experimental details 7
2.1 Materials 7
2.2 Fabrication of Laser-induced Graphene Electrode (LIGE) 7
2.3 Modification of PDMS-transferred LIGE 8
2.4 Electrochemical AST measurement 11
3. Results and discussion 14
3.1 Optimization of Laser-Induced Graphene Formation 14
3.2 Optimization of Transfer Process and Mechanical Flexibility 15
3.3 Effect of Working Electrode Size on Electron Trasnfer Kinetics 16
3.4 Electrode Modification Characterization 18
3.5 Characterization of PDMS Surface Modification 19
3.6 Analytical Performance of the Sensor for AST Detection 22
4. Conclusion 24
References 25